Science and technology

Combined Loading on Press-Fit Fasteners: Pull-Out, Torque and Shear Together

Combined Loading on Press-Fit Fasteners: Pull-Out, Torque and Shear Together

Press-fit fastener data sheets usually list three figures: push-out force, torque-out force and shear force. Designers often pick whichever is closest to their case, apply a safety factor and close the topic. That works for simple duties, but in real structures a press-fit fastener rarely sees one direction of load: a press nut in a panel carries bolt tension, tightening torque and shear from panel weight or vibration. Under combined action the capacity is not a simple sum; it reduces noticeably. Zhuhai Jiali Hardware has assessed many such cases with sheet metal customers, and this article explains how to derive design values.

Why a Single Figure Is Not Enough

Press-fit locking comes from mechanical engagement between knurl teeth and sheet material. Under a single load direction the tooth contact state is relatively stable. When pull-out and torque act together, the tooth faces see normal and tangential stress simultaneously, local contact stress rises sharply, plastic deformation starts earlier, and the observable result is lower pull-out strength than in a single-direction test.

The effect is pronounced in thin sheet and soft materials. Thin sheet provides insufficient constraint, so under torque the material around the teeth bulges locally, and once it bulges the pull-out path shortens. The same fastener in 1.5 mm and 3 mm sheet can therefore differ significantly in combined capacity, and one figure cannot cover both.

Sheet Thickness and Hole Size

Sheet thickness sets the effective engagement length. Published push-out figures assume the recommended thickness; below that, capacity falls roughly linearly, and below the minimum the fastener cannot lock reliably at all. If a design thins the sheet for weight, the fastener capacity must be recalculated rather than carrying over the original data.

Hole size is the second constraint. Too large and the knurl teeth embed too shallowly, reducing both push-out and torque-out; too small and the sheet is over-compressed during pressing, possible micro-cracks around the hole lead to premature failure in service. Hole tolerance must be controlled, and punched holes typically have wider tolerance than drilled ones, so the process must be assessed.

Choosing the Safety Factor

A safety factor is not a number picked from the air; it should reflect uncertainty in three areas: accuracy of load estimation, scatter in material and process, and severity of failure consequence. Crude load estimates, for example static analysis ignoring vibration amplification, need a larger factor; stable material and process with batch data allow a smaller one; severe consequences such as safety parts or load bearing structures demand a large one.

A workable practical approach is to tier the factor: about two for static, non-vibrating, non-safety applications; about three where vibration exists but loads can be measured; four or more where loads cannot be measured or impact is possible. These are starting points, corrected by validation results.

A Simplified Assessment Method

Precise combined loading analysis needs finite elements, which most sheet metal designs do not require. A practical simplification is the load ratio sum: divide actual pull-out by pull-out strength to get ratio a, actual torque by torque strength to get ratio b, and treat a plus b below 0.7 as safe, between 0.7 and 1.0 as requiring validation, and above 1.0 as requiring redesign.

The criterion is empirical rather than derived, but it brings the combined reduction into the assessment approximately. For shear plus pull-out, a similar square root of sum of squares approach applies. The essential point is not to compare a single-direction strength directly against actual load.

Validating Combined Loading with a Simple Test

When the assessment lands in the range needing validation, a simple combined loading test is often more useful than elaborate analysis. Prepare coupons with the same sheet, thickness and hole size, apply the design torque with a torque wrench, then measure push-out force in that state and compare with the untorqued value to obtain the reduction ratio.

No expensive equipment is needed: an ordinary tensile machine and a simple fixture suffice, and the result is direct. Doing this at prototype stage feeds the reduction ratio into the design and avoids changing sheet thickness or fastener size after volume production has started.

Design Measures That Reduce the Load

When assessment shows insufficient combined capacity, options beyond a larger fastener exist. One is to separate torque from pull-out: use anti-loosening features to lower tightening torque, or a shoulder so the bolt does not press directly on the fastener. Another is to add load points and spread the load over several fasteners. A third is to reinforce the sheet around the fastener with an upstand or rib to improve constraint.

These changes are cheap at design stage and painful after volume launch. Zhuhai Jiali Hardware provides load data for various sheet thicknesses and trial press validation in press-fit selection support, helping customers put combined loading values on a verifiable basis instead of a lone specification number.